Oscilloscope

Oscilloscope

Inquire now

Oscilloscope

Click to enlarge image

 Model Number OSC1020

Features

  • Frequency : DC~20 MHz
  • Trigger : 20MHz
  • Deflection Factor : 5mV ~ 5V
  • Sweep Factor : 0.2s ~ 0.1us
  • Vert Trigger
  • Vertical Type : CH1, CH2, DUAL, ADD, ALT, CHOP
  • Trigger Mode : AUTO, NORM, TV-V, TV-H
  • Vertical Sensitivity : 5mV(MAG 1mV)
  • Channel : 2 CH
  • Trace : 2
  • Cooling Fan System
MODEL
OSC1020
CRT
Configuration and
Useful Screen
6-inch Rectangular Screen with Internal Graticule : 8 x 10 div (1 div = 1cm)
Marking for Measurement of Rice Time 2mm Subdivisions along the central axis
Accelerating Potential
+1.9KV Approx. (Ref. Cathode)
Phosphor
P31 (Standard)
Focussing
Possible (With Auto-Focus Correction Circuit)
Trace Rotation
Provided
Intensity Control
Provided
Z-AXIS INPUT
(INTENSITY
MODULATION)
Input Signal
Positive Going Signal Decreases Intensity
+5 Vp-p or
More Signal Cases Noticeable Modulation at Normal Intensity Settings
Bandwidth
DC to 3.5 MHz (-3dB)
Coupling
DC
Input Impedance
20 * 30 Typical
Maximum Input Voltage
30V (DC + Peak AC)
VERTICAL
DEFLECTION
Bandwidth
(-3dB)
DC Coupled
DC to 20 MHz Normal
DC to 10 MHz magnified
AC Coupled
10 Hz to 20 MHz Normal
10 Hz to 10 MHz magnified
Modes
CH1, CH2, DUAL, ADD, ALT, CHOP
Deflection Factor
5mV/div to 5V/div in 11 Calibrated Steps of
A 1-2-5 Sequence
Continuously Variable Between Steps
At Least 1:2.5
Accuracy
Normal : ±3%, Magnified : ±5%
Input Impedance
1 in Parallel with Approx. 30 pF
Maximum Input Voltage
Direct 400V (DC+Peak AC), with Probe : Refer to Probe specification
Input Coupling
DC-GND-AC
Rise Time
17.5ns or Less (35 rs or Less : x5MAG)
CH1 Out
20mV/div into 50° : DC to 10 MHz (-3dB)
Polarity Inversion
CH2 Only
HORIZONTAL DEFLECTION
Display Modes
Normal, X-Y, X 10, Variable
Time Base
0.1° / div to 0.2s / div in 20 Calibrated Steps.
1-2-5 Sequence
Un-Calibrated Continuous Control Between Steps at Least 1:2.5
Sweep Magnification
10 Times (Maximum Sweep Rate : 10 ns /div)
Accuracy
±3%, ±5% (0°C to 40°C), Additional Error for Magnified ±2%
TRIGGER
SYSTEM
Modes
AUTO, NORM, TV-V, TV-H
Source
CH1, VERT (CH1, CH2), EXT, LINE
Coupling
AC
Slope
+ or - or
Sensitivity and
Frequency Auto
(30Hz or More), Nom
- AREA
2 MHz to 20 MHz / DC to 2 MHz
Sensitivity and
Frequency Auto
(30Hz or More), Nom
- INT
1.5 div / 0.5 div
Sensitivity and
Frequency Auto
(30Hz or More), Nom
- EXT
0.6 Vp-p / 0.2 Vp-p
TV-V, TV-H
At Least 1 div or 1.0 Vp-p
External Trigger Input Impedance
1 (in Parallel with Approx. 25 pF)
Max Input Voltage
400V (DC+Peak AC)
X-Y
OPERATION
X-Axis
(same as CH1 Except for the Following) Defection Factor : Same as That of CH1 Accuracy : ±5%
Y-Axis
Same as CH2
X-Y Phase Difference
30 or Less (At DC to 50 KHz)
CALIBRATOR
Probe Adjustment
1 KHz (±20%) Frequency, 0.5V (±10%) Square Wave Duty Ratio : 40~60%
POWER
SUPPLY
Voltage Range
Fuse (250V)
IEC127
F1.25 AL
F0.63 AL
Frequency
50/60 Hz
Power Consumption
Max 45W
PHYSICAL
CHARACTERISTICS
Weight
8.2Kg
Size
370mm (W) x 137mm (H) x 416mm (D)
ENVIRONMENTAL
CHARACTERISTICS
Temperature
Temperature Range for Rated Operation :
+10° to +35° (+50° to +95°)

Max Ambient Operating Temperature :
+0° to +40° (+32° to +104°)
Max Storage Temperature :
-20° to +70° (-4° to +158°)
Humidity
Range for Rated Operation :
45% to 85% RH / Max
Ambient Operating Humidity : 35% to 85% RH
OTHERS
Accessories Supplied
Operator’s Manual : 1 / Spare Fuse : 1
Power Cord : 1 / Test Probe (option) : 2